Kippzonen COMBILOG Data Logger Manuale Utente Pagina 131

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 173
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 130
BYTNUM ..... number of data bytes (max. 64)
D0 - Dn ....... data bytes (max. 64)
CRC ............ check sum
CRC polynomial: u
15
+ u
13
+ 1
CRC start value: hex FFFF
Read Input Register
Description:
By this command input registers (read-only registers) can be
read.
Request Telegram
ADR FNR REGSTA REGNUM CRC
4 MSB LSB MSB LSB MSB LSB
Response Telegram
ADR FNR BYTNUM D0 D1
4
Dn CRC
MSB LSB
ADR ............ module address (hex 00..7F)
FNR ............ function number (hex 04)
REGSTA ..... address of the first register to be read
REGNUM .... number of registers to be read
BYTNUM ..... number of data bytes (max. 64)
D0 - Dn ....... data bytes (max. 64)
CRC ............ check sum
CRC polynomial: u
15
+ u
13
+ 1
CRC start value: hex FFFF
Hardware Manual COMBILOG 1022
131
Vedere la pagina 130
1 2 ... 126 127 128 129 130 131 132 133 134 135 136 ... 172 173

Commenti su questo manuale

Nessun commento