Coding <host input>:
hex 00: host input is not possible
hex 01: host input is possible (tare/reset/dig.out/setpoint
values)
Coding <type of calculation>:
hex 00: normal calculation of average value
hex 01: calculation of average value with wind direction
hex 02: calculation of the sum over the averaging interval
hex 03: continuous sum
hex 04: vectorial average for wind velocity
hex 05: vectorial average for wind direction
read data from channel: length = 2..5 byte
<channel number> binary 1 byte
<channel value Kx> binary 1, 2 or 4 byte
write data to a channel: length = 2..5 byte
<channel number> binary 1 byte
<channel value Px> binary 1, 2 or 4 byte
tare/reset a channel: length = 1 byte
<channel number> binary 1 byte
read, write and tare/reset channels: length 1 byte
<tare/reset> binary 1 byte
<channel value P1> binary 1, 2 or 4 byte
<channel value P2> binary 1, 2 or 4 byte
: . .
Hardware Manual COMBILOG 1022
127